Using the formulas and codes provided by ACI 318 1. Design a square interior column footing...

90.2K

Verified Solution

Question

Civil Engineering

Using the formulas and codes provided by ACI 318
1. Design a square interior column footing for a 15-in. square tiedinterior column that supports a dead load of 160 kips and live loadof 180 kips. The column is reinforced with eight # 8 bars, also,the base of the footing is 6 ft below the grade line, the soilweight is 100 lb/ft3, the concrete weight is 150 lb/ft3, f’c =4,000 psi, fy = 60,000 psi and qa = 4 kip/ft2.

2. What is the importance of providing enough thickness for thefooting of a structure.