In a liquid transmission pipeline, a pump had been designed for a throughput of 10,000 bpd....

50.1K

Verified Solution

Question

Electrical Engineering

In a liquid transmission pipeline, a pump had been designed fora throughput of 10,000 bpd. However the demand has increased by25%. It has been proposed to increase the impeller diameter andspeed in order to meet the new demand. However, the impellerdiameter increase is limited to10%. The original speed of the pumpis 1200 rpm and the original power is 60 kW. Calculate A. The newspeed of the pump. B. The new shaft power of the pump.

Answer & Explanation Solved by verified expert
4.0 Ratings (653 Votes)
Pump demand Q1 10000 bpdAssuming Diameter of impeller    See Answer