Determine the size of the high rate trickling filter for the following data: Sewage flow is...

80.2K

Verified Solution

Question

Civil Engineering

Determine the size of the high rate trickling filter for thefollowing data: Sewage flow is 5 MLD; Recirculation factor is 1.89;Raw wastewater BOD is 230 mg/L; BOD removed in PST is 30%; Finaldesired BOD in the treated effluent is 25 mg/L

pls send the sol fast in rough only i need it urgent

Answer & Explanation Solved by verified expert
4.0 Ratings (483 Votes)