(c) A titanium hip replacement ball joint of 23.000 mm diameter was precision ground and required...

80.2K

Verified Solution

Question

Mechanical Engineering

(c) A titanium hip replacement ball joint of 23.000 mm diameterwas precision ground and required to be finished to a tolerance of+/- 0.002 mm The inspection procedure resulted in the parts beingmeasured whilst still hot at 80 C after grinding. If thecoefficient of linear expansion of titanium is 10 microns/metre degC, determine 1) The linear expansion relative to the referencetemperature of 20 deg C 2) The overall result of measuring partshot on the finished size and the type of engineering fit that mayresult Comment on the likelihood of the +/- 0.002 mm tolerancebeing obtainable and should a correction factor be applied to themeasurement ?

Answer & Explanation Solved by verified expert
3.8 Ratings (584 Votes)
coefficient of linear expantion of the titanium is 10 micron meter that is 001 mm 1000 mm 000001 0c if the titanium ball is finished to the size of 23 mm at 80oC while    See Answer