Question
Accounting
A single level warehouse building has a 5000 m floor area for storage and a two level office attached to one end of the warehouse. The main areas and the activities carried out in the building include: Storage handling (storage) Office works (office) For this question you are required to consider the warehouse only. The capital value of the warehouse as a shell is $3,000,000. The fit out and equipment are valued at $1,500,000. Loss due to warehouse shut down is $15,000 per day. The estimated life span of the building is 30 years. A fire safety systems engineer has come up with the following options for fire protection: System 1 - Sprinklers only Cost of installing sprinklers: $50,000. Maintenance cost: $4,000 per year Update in every 10 years for $20,000. System 2 - Smoke detectors only Cost of installing smoke detectors: $10,000. Maintenance cost: $1,000 per year Update in every 10 years for $6,000. It is assumed that a sprinkler controlled fire would limit the damage and the business could be re-opened within 35 days. However, in the case of an uncontrolled fire (sprinkler failure or no sprinkler at all) the damage would extend to the whole building and it would require 150 days to restore the warehouse function. The discount rate is 10% per year. The frequency of fire starts in a warehouse building is assumed to be 1x10-6/sq-m/year. The reliability of the sprinkler system is assumed to be 0.90. List any other assumptions (if necessary) for data adopted in your calculation. Question 1 1. Analyse the costs and benefits of each of the two systems. Also, identify the more economically viable system. when the reliability of the sprinkler system is not 0.90 anymore but determined based on the following information: The sprinkler system fails if (i) there is no water behind sprinkler heads OR (ii) sprinkler heads are faulty. The probabilities of (i) and (ii) are equally 0.01, and they are statistically independent. The life span of the building is 30 years. Comment on the change. A single level warehouse building has a 5000 m floor area for storage and a two level office attached to one end of the warehouse. The main areas and the activities carried out in the building include: Storage handling (storage) Office works (office) For this question you are required to consider the warehouse only. The capital value of the warehouse as a shell is $3,000,000. The fit out and equipment are valued at $1,500,000. Loss due to warehouse shut down is $15,000 per day. The estimated life span of the building is 30 years. A fire safety systems engineer has come up with the following options for fire protection: System 1 - Sprinklers only Cost of installing sprinklers: $50,000. Maintenance cost: $4,000 per year Update in every 10 years for $20,000. System 2 - Smoke detectors only Cost of installing smoke detectors: $10,000. Maintenance cost: $1,000 per year Update in every 10 years for $6,000. It is assumed that a sprinkler controlled fire would limit the damage and the business could be re-opened within 35 days. However, in the case of an uncontrolled fire (sprinkler failure or no sprinkler at all) the damage would extend to the whole building and it would require 150 days to restore the warehouse function. The discount rate is 10% per year. The frequency of fire starts in a warehouse building is assumed to be 1x10-6/sq-m/year. The reliability of the sprinkler system is assumed to be 0.90. List any other assumptions (if necessary) for data adopted in your calculation. Question 1 1. Analyse the costs and benefits of each of the two systems. Also, identify the more economically viable system. when the reliability of the sprinkler system is not 0.90 anymore but determined based on the following information: The sprinkler system fails if (i) there is no water behind sprinkler heads OR (ii) sprinkler heads are faulty. The probabilities of (i) and (ii) are equally 0.01, and they are statistically independent. The life span of the building is 30 years. Comment on the change
Answer & Explanation
Solved by verified expert
Get Answers to Unlimited Questions
Join us to gain access to millions of questions and expert answers. Enjoy exclusive benefits tailored just for you!
Membership Benefits:
Unlimited Question Access with detailed Answers
Zin AI - 3 Million Words
10 Dall-E 3 Images
20 Plot Generations
Conversation with Dialogue Memory
No Ads, Ever!
Access to Our Best AI Platform: Flex AI - Your personal assistant for all your inquiries!