A horizontal Venturimeter with inlet diameter 300 mm and throat diameter 150 mm is used to...

70.2K

Verified Solution

Question

Civil Engineering

A horizontal Venturimeter with inlet diameter 300 mm and throatdiameter 150 mm is used to measure the flow of water. The pressureat inlet is 24 N/cm2 and the vacuum pressure(p2)at the throat is 320 mm of mercury. Find thedischarge and velocity through the pipe .The value of Cdmay be taken as 0.98.