A horizontal uninsulated steam pipe passes through a large room whose walls and ambient air are...

70.2K

Verified Solution

Question

Mechanical Engineering

A horizontal uninsulated steam pipe passes through a large roomwhose walls and ambient air are at 300 K. The pipe of 125-mmdiameter has an emissivity of 0.85 and an outer surface temperatureof 373 K. Calculate the rate of heat loss per unit length from thepipe.

Answer should be close to 384W/m