A counterflow, concentric tube heat exchanger used for engine cooling has been in service for an...

60.1K

Verified Solution

Question

Mechanical Engineering

A counterflow, concentric tube heat exchanger used for enginecooling has been in service for an extended period of time. Theheat transfer surface area of the exchanger is 5 m2, andthe design value of the overall convection coefficient (without anyfouling) is 38 W/m2K. During a test run, engine oilflowing at 0.1 kg/s is cooled from 110oC to66oC by water supplied at a temperature of25oC and a flow rate of 0.18 kg/s. Determine whetherfouling has occurred during the service period. If so, calculatethe fouling factor, R”f (m2K/W).Specific heat of engine oil is 2166 J/kgK, and water is 4178J/kgK.

What is R”f = x 10-3m2K/W?

Answer & Explanation Solved by verified expert
3.7 Ratings (688 Votes)
    See Answer
Get Answers to Unlimited Questions

Join us to gain access to millions of questions and expert answers. Enjoy exclusive benefits tailored just for you!

Membership Benefits:
  • Unlimited Question Access with detailed Answers
  • Zin AI - 3 Million Words
  • 10 Dall-E 3 Images
  • 20 Plot Generations
  • Conversation with Dialogue Memory
  • No Ads, Ever!
  • Access to Our Best AI Platform: Flex AI - Your personal assistant for all your inquiries!
Become a Member

Other questions asked by students