81. Given: Service drop conductors passing over a swimming pool have a vertical clearance from the...

60.1K

Verified Solution

Question

Electrical Engineering

81. Given: Service drop conductors passing over a swimming poolhave a vertical clearance from the water surface of 18 ft. theseconductors must be located a minimum of _____ ft. horizontally fromthe outer edge of the swimming pool.

A. 0

B. 10

C. 15

D. 22.5

82. What is the full load current in amperes for a 1-hpsingle-phase, 115-volt, AC motor?

A. 2.1

B. 8

C. 8.4

D. 16

83. If a branch circuit supplies a single 14-amperenon-motor-operated appliance without an over current protectionrating, the rating of the over current protection shall not exceed_____ percent of the appliance rated current.

A. 90

B. 100

C. 125

D. 150

84. What is the maximum overcurrent protection rate in amperespermitted for an appliance without a motor that has an input ratingof 40 amperes?

A. 30

B. 40

C. 50

D. 60

85. The overload protection for a 3-phase, 25 Hp, 480-volt motorshall be selected

A. from the motor nameplate full load current

B. from the full load current in table 430-150 of the NEC

C. from the locked-rotor current in table 430-150 of the NEC

D. as a percentage of the motor branch-circuit overcurrentprotection

86. Branch-circuit conductors that serve a 3-phase, 230-volt, 15ph induction-type motor shall have an allowance ampacity of atleast _____ amperes.

A. 42

B. 46.2

C. 52. 5

D. 60.5

87. Disregarding exceptions, where the design and operation of agenerator does not prevent overloading the ampacity of theundergrounded phase conductors shall be at least ______ percent ofthe name plate current rating of the generator.

A. 80

B. 100

C. 115

D. 125

88. A circuit that supplies a 1/2 -hp motor that operatesutilization equipment fastened in place in conjunction with otherloads shall be calculated by adding the sum of the other loads plus_____ percent of the largest motor.

A. 100

B. 125

C. 150

D. 175

89. When the design and operation of the generator will preventoverloading the conductors shall not be less than ______>

A. the same hp as the generator

B. 100 percent of nameplate current

C. 115 percent of nameplate current

D. 115 percent of the hp of the generator

90. Transformers for sight located in an attic or soffit shallhave a permanent walkway of at least _____ in. wide.

A. 12

B. 18

C. 24

D. 36

Answer & Explanation Solved by verified expert
4.3 Ratings (550 Votes)
81 Given Service drop conductors passing over a swimming pool have a vertical clearance from the water surface of 18 ft these conductors must be located a minimum of ft horizontally from the outer edge of the swimming pool A 0 B 10 C 15 D 225 Answer Overhead networkpowered broadband communication systems conductors minimum clearance is 225 ft from the waters edge of swimming    See Answer
Get Answers to Unlimited Questions

Join us to gain access to millions of questions and expert answers. Enjoy exclusive benefits tailored just for you!

Membership Benefits:
  • Unlimited Question Access with detailed Answers
  • Zin AI - 3 Million Words
  • 10 Dall-E 3 Images
  • 20 Plot Generations
  • Conversation with Dialogue Memory
  • No Ads, Ever!
  • Access to Our Best AI Platform: Flex AI - Your personal assistant for all your inquiries!
Become a Member

Other questions asked by students